8-Outlet eco PDU

8-Outlet eco PDU

Product Code : PE6108AV

Brand Category : Rack PDU


Description


  • Connections
    • Detachable front panel fits 19” racks with different depths
    • Built-in 10/100 Mbit Ethernet Interface
    • Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, and V3, Telnet
    • 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS
    • Browser access via IE, Firefox, Chrome, Safari, and more
    • Easy integration with ATEN Control System and Control4 libraries
    • Supports RS-232 port and power outlet control (on/off) by outlet group.



  • Metering
    • 1% Metering Accuracy – supports bank-level power metering
    • Environment Monitoring – supports external temperature or temperature and humidity sensors for rack temperature and humidity monitoring



  • Outlet Switch Control
    • Remote and local power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
    • Multiple Power Control Methods – Wake on LAN, System After AC Back, Kill the Power
    • Power-On Sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order to enhance equipment safety
    • Proactive Overload Protection (POP) :
      - automatically powers off outlets when current overloads to protect operating devices.
      - Priority Mode enables outlets to be powered off following the outlet shutdown order pre-defiend by the administrator via web browser
    • Auto Ping – the method pings a device at specified intervals, and if there is no response (request timed out), the PDU automatically powers cycles the outlet (off and then on)
    • Holiday Mode – when Holiday Mode is enabled, each outlet will be set to the selection chosen for it: POWER OFF or POWER ON



  • eco DC Energy & DCIM Management Web GUI*
    • Automatic discovery of all ATEN PDUs within the same intranet
    • Remote real-time power measurement and monitoring of PDUs
    • Real-time environment monitoring via sensors
    • Plotting and monitoring of all ATEN PDU devices
    • Exceed threshold alerts through real-time monitoring, SMTP, and System logs
    • Power analysis reports
      * eco DC is designed to work with ATEN eco PDUs and is bundled with all PE Series models.

Add to Query Cart PDF Download


Technical Specification


Electrical
Nominal Input Voltage100 – 120 VAC
Maximum Input Current15A(Max), 12A(UL de-rated)
Input Frequency50-60 Hz
Input ConnectionFor A/J Plug:NEMA 5-15P
Input Power1800VA(Max),1440VA(UL de-rated)
Outlet TypeTotal : 8 x NEMA 5-15R
Nominal Output Voltage100-120 VAC
Maximum Output Current (Outlet)NEMA 5-15R : 15A (Max) 12A (UL de-rated)
Maximum Output Current (Bank)15A (Max) 12A (UL de-rated)
Maximum Output Current (Total)15A (Max) 12A (UL de-rated)
MeteringPer Bank level Current, Voltage, VA , PF and KWh Monitoring
Outlet SwitchingYes
Environment Sensor Ports2
Metering AccuracyVoltage range: 100VAC ~ 250VAC +/-1%
Power range: 100W ~ 5000W +/- 2%
Current range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Communication
10/100 Mbps1 x RJ-45
RS-2321 x DB-9
Switches
PowerYes
Environmental
Temperature (Operating / Storage)0 – 45℃ / -20 – 60℃
Humidity (Operating & Storage)0–80% RH, Non-Condensing
Physical Properties
Dimensions (L x W x H)43.24 x 26.73 x 4.40 cm
(17.02 x 10.52 x 1.73 in.)
Weight3.70 kg ( 8.15 lb )
Power Cord Length3 m
Compliance
EMC VerificationFCC, J55022
Safety VerificationPSE

Hot Products